Compliance·4 pages
LOLER Duty-Holder Checklist
Use this checklist to verify Thorough Examination intervals, defect-tracking processes, Competent Person arrangements, RIDDOR triggers and documentation requirements across your portfolio.
This checklist is designed to be printed, photocopied and worked through site-by-site. Tick each line as evidence is gathered; flag anything you cannot answer for your next contractor or insurer review.
1. Competent Person & inspection regime
- Competent Person identified in writing — independent of maintenance contractor
- Thorough Examination interval recorded (6 months for passenger lifts, 12 months for goods)
- Most recent Examination report on file and accessible at the lift
- Schedule of next four Examinations diarised
- Replacement Competent Person procedure documented
2. Defect tracking & remediation
- All open Category A, B and C defects logged in a single tracker
- Each defect has a named owner, target date and evidence of completion
- Maintenance contract scope confirmed against typical Cat B/C remedial works
- Out-of-scope works quoting process agreed in advance
- Trend analysis reviewed annually for modernisation candidates
3. Documentation & audit trail
- EC Declaration of Conformity / installation certificate retained
- Annual maintenance reports retained for minimum 6 years
- Site-specific risk assessment & method statement (RAMS) on file
- Lift identification plate present, legible and accurate
- Operating instructions and emergency-release procedure displayed
4. Emergency procedures & RIDDOR
- Documented passenger-release procedure for each lift
- 24/7 emergency contact number prominently displayed
- RIDDOR-reportable incident definition understood by site team
- Process for taking a lift out of service following a Cat A defect
- Insurer-notification trigger points agreed
5. Annual portfolio review
- Total lift count, by type, by site, on a single register
- Maintenance spend per lift trended year-on-year
- Modernisation candidates identified from defect-pattern review
- Compliance evidence pack assembled for board / insurer review
- Contractor performance reviewed against KPIs (response, attendance, repeat fixes)
Next step
Need help working through this for a specific portfolio? Our engineers can audit a single building or a multi-site estate and produce the defect-pattern report for you.
Get in touch© Technical Lift Services Ltd · Company No. 10289924tlse.co.uk · 0330 043 3484